Custom Search
 
  
 


TM 9-2330-380-14&P
D. INSTALLATION OF RECEPTACLE CONNECTORS
1. Install the connector receptacle, P/N 10937538 (20), in the electrical junction box (3) in the front of the
semitrailer. Strip the insulation from each of the three wires (15), (16), and (17) per the strip guage
molded into the back of the connector receptacle (20). Insert the black wire (15) into one of the holes
under the dark screws on one side of the outlet and tighten the screw until the wire is secure. Insert
the white wire (17) into a hole under the light screws on the opposite side of the connector receplacle
(20) and tighten the screw until the wire is secure. Loop the green wire (16) under the green ground-
ing screw and tighten the screw until the wire is secure.
2. Push the connector recepacle (20) into the electrical junction box (3) and fasten in place with the
machine screws provided with the recepacle (20).
3
15
21
16
17
20
3. Go to the next electrical junction box (3) and pull down enough wire to make the connections to the connec-
tor receptacle (20). Cut the wires, (15), (16), and (17) at the appropriate point and strip insulation from the
ends of all wires per the strip guage molded into the back of the connector recepacle (20).
3
15
15
16 17
16
17
20
J-5



 


Privacy Statement - Copyright Information. - Contact Us

Integrated Publishing, Inc. - A (SDVOSB) Service Disabled Veteran Owned Small Business