5. Install retaining straps, P/N E977DC (13), using two tapping screws, P/N MS51861-49 (14), as required to
provide proper mounting and support to the flexible conduit (8), as required. Recommend a minimum of one
every 4 feet (1.22 M) of distance between electrical boxes.
14
13
D. INSTALLATION OF ELECTRICAL WIRE
1. Take one end of each of approximately 40 feet (12.2 M) electrical wires, P/N M5086/1-12-0 (Black) (15),
P/N M5086/1-12-5 (Green) (16), and P/N M5086/1-12-9 (White) (17), and lay them side by side. Using
electrical tape (18), secure one end of wires together.
2. Using the taped end (18), guide the wires through the circuit breaker box (12), connector assembly (19),
flexible conduit (8), and junction box assemblies (3) until reaching the single junction box at the front of the
semitrailer.
8
3
8
12
19
18
15
16
17
J-4



 