Tweet |
Custom Search
|
|
|
||
TM 9-2330-330-14&P
FILTER/SEPARATOR SUMP MAINTENANCE
THIS WP COVERS:
Draining Filter/Separator Sump, Follow-On Task
INITIAL SETUP:
Maintenance Level
Tools and Special Tools
Operator
Suitable container (item 1, WP 0171 00)
Materials/Parts
Equipment Conditions
Rags (item 11, WP 0174 00)
Semitrailer disconnected from prime mover (refer
to WP 0007 00)
Semitrailer grounded (refer to WP 0007 00)
DRAINING SUMP
NOTE
Place suitable container under sump before, during,
and after operation.
Place suitable container under valve N (3) of filter/separator sump (2). Open valve N (3) to drain water
from filter/separator (1) after each period of operation (refer to WP 0007 00).
FOLLOW-ON TASK
Disconnect semitrailer grounding cables (WP 0007 00).
END OF TASK
0040 00-1/2 blank
|
||