Tweet |
Custom Search
|
|
|
||
TM 9-2330-330-14&P
ENGINE AIR FILTER CLEANER MAINTENANCE--Continued
0039 00
CLEANING AND INSPECTION
1.
Check filter element for rips, tears, or holes. Replace element if damaged.
WARNING
Compressed air should be used for cleaning purposes
and should not exceed 30 psi (207Pa). Use only with
effective chip-guarding and personal protective equipment
(e.g., goggles/shield and gloves). Failure to follow this
warning may result in injury to personnel.
2.
Clean filter element with low-pressure compressed air directed inside filter element.
3.
Wipe inside of air cleaner with clean, damp rag.
ASSEMBLY
1.
Install engine air filter element (3) and wingnut (4) to air cleaner (1).
2.
Install baffle (5) to dust cap (6).
3.
Install dust cap (6) and tighten air cleaner housing clamp (2) to air cleaner (1).
FOLLOW-ON TASK
Disconnect semitrailer grounding cables (WP 0007 00).
END OF TASK
0039 00-2
|
||