Custom Search
 
  
 


TM 9-2330-330-14&P
PIPING CONTROL COMPONENTS TROUBLESHOOTING
THIS WP COVERS:
Piping Control Components Troubleshooting
INITIAL SETUP:
Maintenance Level
References
Organizational
To troubleshoot the M969A3 piping control components, perform the test/inspections and corrective
actions provided in Table 1.
Table 1. Troubleshooting Procedures.
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
WITH EMERGENCY VALVE A
1.
Verify all valves are set per
Set valves per schematic on tool
HANDLE IN CLOSED
fuel operations schematic
box lid (refer to WP 0007 00). If
POSITION, FUEL CONTINUES
on tool box lid (refer to WP
valves are set properly, go to
TO FLOW OUT OF TANK
step 2.
2.
Move handle and observe
If lever movement is observed
valve A lever movement at
and fuel flow stops, verify
valve A under tank (refer to
problem is solved. If fuel
continues to flow, notify Direct
Support maintenance.
END OF TASK



 


Privacy Statement - Copyright Information. - Contact Us

Integrated Publishing, Inc. - A (SDVOSB) Service Disabled Veteran Owned Small Business