Custom Search
 
  
 


TM 9-2330-330-14&P
FILTER/SEPARATOR TROUBLESHOOTING
THIS WP COVERS:
Filter/Separator Troubleshooting
INITIAL SETUP:
Maintenance Level
References
Organizational
To troubleshoot the M969A3 filter/separator, perform the test/inspections and corrective actions provided
in Table 1.
Table 1. Troubleshooting Procedures.
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
FUEL DOES NOT FLOW
1.
Verify all valves are set per
Set valves per schematic on tool
DURING FILTERED FUEL
fuel operations schematic
box lid (refer to WP 0007 00). If
SERVICING OPERATION
on tool box lid (refer to WP
valves are already set per fuel
operations schematic, go to
step 2.
2.
Check reading of
If gage reads 1725 psi (117
filter/separator gage.
123 kPa), replace clogged fuses.
Verify problem is solved. If gage
is in normal range, troubleshoot
centrifugal pump.
END OF TASK



 