TM 9-2330-329-14&P
ENGINE TROUBLESHOOTING
THIS WP COVERS:
Engine Troubleshooting
INITIAL SETUP:
Maintenance Level
References
Operator/Crew
To troubleshoot the M967A2 engine, perform the test/inspections and corrective actions provided in Table
1.
Table 1. Troubleshooting Procedures.
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
1.
ENGINE WILL NOT TURN 1.
Set engine switch on
If battery voltage gage indicates
OVER
control panel to RUN and
less than 2428 V dc,
check battery voltage
notify Organizational
gage.
maintenance. If battery
gage voltage is okay, go to
step 2.
2.
Remove battery cover and
If cables are corroded, frayed, or
check for loose, frayed, or
broken, notify
corroded battery cable
Organizational
connections.
maintenance. If cables are
okay, go to step 3.
3.
Remove vent fill caps from If electrolyte is low, notify
batteries and check for low Organizational maintenance.
electrolyte.
2.
ENGINE IS HARD TO
1.
Set engine switch on
If battery voltage gage indicates
START OR TURNS OVER
control panel to RUN and
less than 2428 V dc, notify
SLOWLY
check battery voltage
Organizational maintenance. If
gage.
battery voltage gage is okay, go
to step 2.
2.
Remove battery cover and
If cables are corroded, frayed, or
check for loose, frayed, or
loose, notify Organizational
corroded battery cable
maintenance. If cables are okay,
connections.
go to step 3.