Custom Search
 
  
 


TM 9-2330-329-14&P
OPERATION UNDER USUAL CONDITIONS--Continued
0007 00
G.
ENGINE OPERATING PROCEDURES
1.
Before starting engine, check fuel level in fuel tank (3). Add fuel as necessary.
2.
Check oil level. If dipstick (1) reads L (low), refer to WP 0034 00.
3.
Check air cleaner restriction indicator (2). If restriction indicator is red, clean or replace engine air
filter per WP 0038 00.
Cold Engine Start
4.
Turn engine run switch (6) to RUN position.
5.
Turn preheater switch (4) to ON position and hold for 1 minute.
6.
Turn starter switch (5) to START position while holding preheater switch (4) in ON position.
NOTE
Do not hold starter switch in START position for more
than 10 seconds.
7.
If engine starts, release starter switch (5) and turn preheater switch (4) to OFF position.
0007 00-9



 