2-129. POST OPERATION PROCEDURES.
a. If system was pumping seawater, dirty water, alkaline water, or foam,
flush the pump with clean water.
WARNING
Make sure system pressure gages and hose pressure
gages are at zero prior to disconnecting any suction or
discharge hoses or removing caps. System operates at
extreme pressure and failure to comply may result in
injury or death to personnel.
b. Make sure all valve controls are in CLOSED position.
c. Disconnect and stow all suction and discharge hoses.
CAUTION
Make sure pump is completely drained in freezing
weather (para 2-134). Water could freeze and expand,
which may cause damage to water pump.
NOTE
Perform steps d. through i. if leaving vehicle in a "Dry
Pump" condition (standby condition, dry condition, water
tank full).
tfft00530P
1
d. Open MASTER DRAIN valve (1) to relieve pressure.



 