Custom Search
 
  
 


TM 9-2330-380-14&P
INSTALLATION OF 110-VOLT INTERIOR POWER RECEPTACLES
J-1. Scope
This appendix provides installation instructions for M129A4 semitrailers without 110-volt power receptacles
previously installed.
J-2. General
A. Using units are authorized to requisition and request Direct Support maintenance facilities to install 110-volt
power receptacles if required by the unit mission and authorized by the Unit Commander.
B. The using unit will requisition and fund the purchase of the parts necessary for installation.
C. The Direct Support unit will install the 110-volt power receptacles after all parts have been received and
provided to them.
D. See Appendix F, Figure 6 for a list of required part National Stock Numbers.
J-3. Installation
A. ELECTRICAL JUNCTION BOX ASSEMBLY
1. Cut 11 pieces of PVC pipe, Schedule 40, electrical conduit, 1 1/2 inches (3.81 cm) long (1). After cutting,
remove all burrs, shavings, and dust. These 1 1/2 inches (3.81 cm) lengths of conduit will serve as connec-
tors between the junction boxes. 10 are for the for junction boxes, P/N E981DFN (2), and one is for the
last junction box, P/N E980DFN (3).
2. Glue two 1 1/2" pieces of conduit (1) in the end of each junction box, P/N E981DFN (2). Glue one 1 1/2"
piece of conduit (1), in the end of the last junction box, P/N E980DFN (3). This junction box is used as the
terminator for the curcuit.
3. Glue two female adapters, P/N E942D (4), on the end of the 1 1/2" conduit pieces (1). These serve as
mounting points for the compression nut connectors, used later.
2
4
1
3
1
4
1
4



 


Privacy Statement - Copyright Information. - Contact Us

Integrated Publishing, Inc. - A (SDVOSB) Service Disabled Veteran Owned Small Business