Tweet |
Custom Search
|
|
|
||
TM 9-2330-380-14&P
4-27. 110-Volt Circuit Breaker Box (M129A4 Only) (cont'd).
5
2. Remove large and small bondnuts (3 & 4).
3. Remove four blind rivets (5) and pull off circuit breaker
box (6).
b. Cleaning and Inspection
1. Wipe parts clean with clean rag (item 14, Appendix E).
2. Inspect for corrosion, frayed wire or other damage.
Replace damaged or defective parts.
3. Inspect for corroded or missing contacts, cracked housing.
Replace damaged or defective parts.
7
c. Repair
NOTE
All circuit breakers are removed/installed in the same
manner. One is shown.
8
3
Pull out circuit breaker (7). Tag and disconnect wire (8).
4
6
d. Installation
4-1
1. Connect wire (8). Install circuit breaker (7).
2. Position circuit breaker box (6) and secure with four blind
rivets (5).
3. Install large and small bondnuts (3 & 4).
4. Position cover (2) and secure with screw (1).
Follow on Maintenance: None
4-39
|
||