0019 00
 
Table 4. Organizational PMCS - Continued 
ITEM TO BE 
ITEM 
MAN- 
EQUIPMENT 
CHECKED OR 
PROCEDURE 
NO.  INTERVAL HOUR 
NOT READY/ 
SERVICED 
AVAILABLE IF: 
CAUTION 
 Do not use paints or 
solvents on hubodometer 
polycarbonate face. 
 Do not stand on 
hubodometer. 
NOTE 
 If hubodometer has a bent or 
stripped stud, case damage, 
improper bracket, or hardware 
or case tampering, it will 
not perform properly. 
 This should be checked 
every 6,000 miles or semian- 
nually, whichever period is 
shorter. 
Check hubodometer bracket and gage 
Semi- 
Hubodometer 
11 
.10 
for looseness and missing hardware. 
Annually 
Torque gage nut to 15 lb-ft (20.3 Nm) 
max. 
NOTE 
 This should be checked 
every 6,000 miles or semian- 
nually, whichever period 
is shorter. 
 Inside of hub cap should 
have a light coat of grease. 
Hub cap leaks or 
Check hub caps for leaks, damage, 
12 
Semi- 
.10 
Hub Caps 
and missing hardware and torque nuts 
is missing. 
Annually 
to 15 lb-ft (20.3 Nm) max. 
0019 00-8
 
 | 
			||
![]()  | 
		||