Custom Search
 
  
 


TM 9-2330-331-14&P
0019 00
Table 4. Organizational PMCS - Continued
ITEM TO BE
ITEM
MAN­
EQUIPMENT
CHECKED OR
PROCEDURE
NO.  INTERVAL HOUR
NOT READY/
SERVICED
AVAILABLE IF:
NOTE
This should be checked
every 6,000 miles or
semiannually, whichever
period is shorter.
Semi-
Main Electrical
Check conditions of electrical harness
9
.25
Harness is worn
Annually
for wear, frayed insulation, corrosion,
through, corroded,
Harness and All
and that connectors are secured. Use
or unsecured.
Electrical
corrosion preventive compounds
Electrical
Connections
(dielectric) on all electrical contacts.
connections are
loose or corroded.
NOTE
This should be checked
every 6,000 miles or
semiannually, whichever
period is shorter.
a. Check for missing or damaged
.25
Leaf Springs and
Leaf spring
Semi-
10
Annually
hangers, end caps, spring seats,
attachments or
Attaching Parts
adjustment plates, trunnion bushings,
hardware is missing
and hardware.
or damaged.
b. Check for the following:
1. Any leaf or portion of any leaf in
Leaf or leaves are
any spring assembly is missing,
missing, separated,
separated, or broken.
or broken.
NOTE
A small protrusion of the trunnion
bushing around trunnion cap is
normal.
2. Visually inspect rubber trunnion
Rubber trunnion
bushing to ensure it is not missing
bushing is missing.
causing metal to metal contact.
0019 00-7



 


Privacy Statement - Copyright Information. - Contact Us

Integrated Publishing, Inc. - A (SDVOSB) Service Disabled Veteran Owned Small Business