Custom Search
 
  
 


TM 9-2330-330-14&P
CLEANING/INSPECTION
1. Rinse inside of filter separator with a clean gallon of the fuel being carried in tanker.
2. Wipe out inside of filter separator and all components being reused with a clean lint free cloth.
3. Inspect for damaged support rods and guide pipes.
4. Inspect water detection float for damage and free movement.
ASSEMBLY
NOTE
Step 1 is not required if full assembly is being reused.
1.
Install bolt (32), washer (31), guide bar (27), washer (30), new lockwasher (29), and nut (28) to
retaining plate (10).
2.
Install gasket (24) and go- no go fuse mounting plate (23) into adapter (25).
3.
Lubricate O-ring on bottom of three new go-no go fuses (20) and mount mounting plate (23).
4.
Install gasket (22) over new go-no go fuses (20) and push into adapter (25).
5.
Install fuse bracket (21) onto go-no go fuses (20).
6.
Install fuse canister (16) over go-no go fuses (20).
7.
Repeat steps 2 through 6 for four remaining filter assemblies (16).
0125 00-5



 


Privacy Statement - Copyright Information. - Contact Us

Integrated Publishing, Inc. - A (SDVOSB) Service Disabled Veteran Owned Small Business