TM 9-2330-330-14&P
WATER DETECTION SWITCH AND HARNESS MAINTENANCE--Continued
0060 00
5.
Remove nut (13) from water detection switch conduit (14) and remove conduit from switch (11).
6.
Disconnect two wires (12) from water detection switch (11).
NOTE
Connectors must be removed from harness leads in order
to fit through conduit.
7.
At junction box (8) pull two wires (4) from water level warning indicator light (5) at control panel (3)
through conduit (15) and wires (12) from water detection switch (11) through conduit (14).