TM 9-2330-330-14&P
OPERATOR/CREW PREVENTIVE MAINTENANCE
CHECKS AND SERVICES (PMCS)--Continued
0034 00
Table 1. Operator/Crew PMCS--Continued.
ITEM NO.
INTERVAL
ITEM TO BE
PROCEDURE
NOT FULLY MISSION
INSPECTED
CAPABLE IF:
29--Continued
During
Control Panel
c.
Check gages for
proper operation as
follows:
Fuel pressure gage
4.
Fuel pressure
gage should read reads below 12 or
12 to 14 psi (83 to above 14 psi
consistently.
97 kPa).
Pump pressure gage is
5.
Pump pressure
not functioning
gage should read
properly during
no less than 30
pumping operations.
psi (207 kPa) for
pump.
Filter/separator gage
6.
Check filter/
indicates 20 psi
separator gage.
(138 kPa) or higher.
d.
Check control panel
light for proper
operations.
30
During
Emergency
Emergency valve
Make sure all valves are
Valve and Vent
handle will not actuate
closed. Operate emergency
emergency valve
handle, and make sure
shutoff lever.
cable is actuating
emergency valve shutoff
lever fully and opens vent
on top of semitrailer.
31
After
Exterior of
Hardware is loose,
a.
Walk around
semitrailer
missing, or damaged.
semitrailer. Check for
loose, missing, or
damaged hardware.
Any leak is evident.
b.
Check for evidence of
any leak
32
After
Piping System
Any pipe is damaged
a.
Inspect all pipes for
to the extent that fuel
dents or cracks.
flow will be restricted.
b.
Drain water from N and
J valves.
0034 00-12