Custom Search
 
  
 


TM 9-2330-330-14&P
OPERATOR/CREW PREVENTIVE MAINTENANCE
CHECKS AND SERVICES (PMCS)--Continued
0034 00
Table 1. Operator/Crew PMCS--Continued.
ITEM NO.
INTERVAL
ITEM TO BE
PROCEDURE
NOT FULLY
INSPECTED
MISSION
CAPABLE IF:
WARNING
When filling tank by means of bottom loading, or self-loading, a test of the precheck system is
mandatory. If this system is not functioning, stop all operations. Determine the problem and have
it corrected by a qualified technician. Failure of automatic shutoff to function may cause
uncontrolled fuel spillage, fire, and/or explosion, resulting in serious injury or death to personnel.
Loading precheck
28
During
Loading
Check operation of upper level
does not operate.
Precheck
sensor.
(D Valve)
29
During
Control Panel
a.
Check switches for proper Any switch does
operation.
not work.
b.
Check to see that preheat
Preheat indicator
indicator light is lit when
light is not lit.
engine is preheating.
c.
Check gages for proper
operation as follows.
1.
operation.
inoperative or
operates
erratically.
Voltage gage reads
2.
Battery voltage
below 24 V dc or
gage should read
above 28 V dc
24 to 28 V dc with
consistently.
engine running.
Oil pressure gage
3.
Oil pressure gage
reads below 30 psi
should read 30 to
(276 kPa), or
95 psi
above 95 psi
(207 to 655 kPa) at
(655 kPa).
normal operating
temperature
0034 00-11



 


Privacy Statement - Copyright Information. - Contact Us

Integrated Publishing, Inc. - A (SDVOSB) Service Disabled Veteran Owned Small Business