TM 9-2330-330-14&P
a. Remove fire extinguishers (1) and bring them to the point of operation.
b. Ground and bond semitrailer per para. C (WP 0007 00-6).
c.
Remove one or both vapor recovery system caps.
d. Start engine (para. G). When engine is warm, adjust to idle speed (10001200 rpm).
e. Remove 4-in. hose (2) from hose tube (3) and connect hose (2) between outlet B (7) and
fuel storage facility.
f.
Open valves B, D, E, and G (6, 8, 4, and 5).
g. Adjust engine to desired flow rate (290320 gpm [10981211 Lpm] @ 22002400 rpm).
OPERATION UNDER USUAL CONDITIONS--Continued
h. After flow has begun, set valve D (8) to the closed position to precheck automatic shut off.
If shut off isfunctional, flow should stop after 2025 seconds. Open valve D; flow should
resume in 2025 seconds.
WARNING
If fuel flow into semitrailer stops because of a shut off
malfunction, or the presence of leaks, or if any other unusual
conditions are observed, stop fuel supply at loading facility
and notify your supervisor.
i.
When tank is full, flow will stop automatically.
0007 00-18



 