Custom Search
 
  
 


TM 9-2330-330-14&P
l.
Disconnect curbside facility vapor recovery hose and cap (3) vehicle vapor recovery outlet.
m. Close all valves.
n. Return fire extinguishers (4) to their covers and brackets.
o. Disconnect bonding and grounding cables.
p. Deactivate whichever brake control valve (2) was functioning in step 1.
OPERATION UNDER USUAL CONDITIONS--Continued
3.
GRAVITY UNLOAD
WARNING
Remove vent cap from either side of vapor recovery tube
to vent tank during pumping operations.
NOTE
Operations begin and end with all valves closed.
a. Remove all fire extinguishers (1) and bring them to the point of operation.
b. Ground and bond semitrailer per para. C (WP 0007 00-6).
c.
Remove 4-in. hose (2) from hose tube (3) and connect hose between outlet B (7) and
fuel facility.
d. Remove one or both vapor recovery system caps.
e. Open valves A, B, D, G, and H (9, 6, 10, 5, and 8).
0007 00-15



 