1.
Place push rod (20) and new gasket (22) to internal valve (21).
NOTE
Have an assistant guide top of push rod into vent valve at top of tank.
Apply antiseize compound to threads.
2.
Install line (19) and fitting (18) to internal valve (21).
3.
Install new gasket (22), elbow (12), eight washers (3), and new self-locking nuts (2) to studs (4).
4.
Install new seal (8), two nuts (6), bolts (5), and split coupling (7) to pipe (9).
5.
Install fitting (10) and cable (15) to cable support (11).
6.
Install cable (15), U-bolt (14), reinforcing plate (16), fuse plate (17), and two nuts (13) to lever (1).