Custom Search
 
  
 


TM 9-2330-329-14&P
ALTERNATOR AND CHARGING CIRCUIT TROUBLESHOOTING--Continued
0026 00
Table 1. Troubleshooting Procedures--Continued
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
5.
1.
Check for loose pulley or
Tighten mounting bolts and if
mounting bolts (refer to
pulley is loose, replace alternator
(refer to WP 0110 00). Verify
problem is solved. If mounting
bolts or drive pulley were okay,
go to step 2.
2.
Check for worn or sticking
If bearings are worn or sticking,
bearings by removing
replace alternator (refer to
alternator belt and spinning
WP 0110 00). Verify problem is
alternator by hand (refer to
solved.
END OF TASK



 