To troubleshoot the M967A2 light systems, perform the test/inspections and corrective actions provided in
Table 1.
Table 1. Troubleshooting Procedures.
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
1.
ALL SEMITRAILER
At front access hatch cover,
Clean/tighten receptacle ground
LIGHTS ARE
check for loose/dirty or corroded
or terminal strip leads. Verify
INOPERABLE/DIM OR
receptacle ground leads and
problem is solved.
FLICKERING
terminal strip leads (refer to WP
NOTE
Refer to WP 0044 00 for
routing of electrical wires
and electrical schematic.
2.
ONE OR MORE LIGHTS
1.
At front access hatch
Clean/tighten receptacle ground
WILL NOT OPERATE
cover, check for loose/dirty or
or terminal strip leads. Verify
corroded receptacle ground
problem is solved. If loose/dirty
leads and terminal strip leads
or corroded leads are not
(refer to WP 0056 00).
present, go to step 2.



 