Custom Search
 
  
 


TM 9-2330-329-14&P
OPERATION UNDER USUAL CONDITIONS--Continued
0007 00
5.
BULK DELIVERY
CAUTION
Remove vent cap from either side of vapor recovery
tube to vent tank during pumping operations.
NOTE
Use this procedure to pump fuel from semitrailer to
storage facility.
Operation begins and ends with all valves closed.
a.
Remove fire extinguishers (1) and bring them to the point of operation.
b.
Ground semitrailer per para. C.
c.
Remove one or both vapor recovery system caps.
d.
Start engine (para. G). When engine is warm, adjust to idle speed (10001200 rpm).
e.
Remove 4-in. hose (3) from hose tube (2) and connect hose (3) between outlet B (4) and fuel
storage facility.
f.
Pull emergency valve A control handle (7) to open position. Open valves B, F, and H (4, 5,
and 6).
g.
Adjust engine speed to desired flow rate (290320 gpm [10981211 Lpm] @ 22002400
rpm).
h.
Shut off engine after delivery is complete.
i.
Close all valves and vapor recovery system vent caps.
j.
Drain hose (3) into suitable container.
k.
Remove and store hose (3) in hose tube (2).
l.
Remove grounding cables.
m.
Store and cover fire extinguisher (1).
0007 00-21



 


Privacy Statement - Copyright Information. - Contact Us

Integrated Publishing, Inc. - A (SDVOSB) Service Disabled Veteran Owned Small Business