Custom Search
 
  
 


TM 9-2330-329-14&P
OPERATION UNDER USUAL CONDITIONS--Continued
0007 00
3.
GRAVITY UNLOAD
WARNING
Remove vent cap from either side of vapor recovery
tube to vent tank during pumping operations.
NOTE
Operations begin and end with all valves closed.
a.
Remove all fire extinguishers (1) and bring them to the point of operation.
b.
Ground semitrailer per para. C above.
c.
Remove 4-in. hose (2) from hose tube (3) and connect hose between outlet B (9) and fuel
facility.
d.
Remove one or both vapor recovery system caps.
e.
Open valves A, B, D, G, and H (8, 6, 10, 5, and 7).
f.
At end of operation close all valves and drain 4-in. hose (2) into suitable container.
g.
Remove and store hose (2) in hose tube (3).
h.
Close vapor recovery system caps.
i.
Remove grounding cables.
j.
Store and cover fire extinguishers (1).
0007 00-17



 