TM 9-2330-326-14&P
Table 4-1. Unit PMCS (Cont.)
ITEM
INTERVAL
ITEM TO
EQUIPMENT NOT
NO.
M
S
A
T
MI
CHECK/SERVICE
PROCEDURE
READY/
AVAILABLE IF:
CAUTION
Direct Support maintenance:
When replacing kingpin, inspect
all supporting structures for rust,
broken welds, and proper
drainage. Structure area interior
must be inspected and protected
against rust. Proper drainage
must be maintained.
7.
The area against the bolster
3
Kingpin
Damage meets or
plate and locking area on the
(Cont.)
(Cont.)
exceeds criteria.
kingpin should have no more
than 10 burrs, nicks, or gouges
that exceed 0.06 in. (1.5 mm) in
depth on the entire surface
area. If this criteria is met or
exceeded, replace the kingpin.
Notify
Direct
Support
maintenance.
Any burrs, nicks or gouges that meet
Damage meets or
or exceed 0.25" (6.4 mm) in length will
exceeds criteria.
require replacement of the kingpin.
Notify Direct Support maintenance.
4
M
S
A
T
MI
Converter
Check converter box and internal wiring  Wiring damaged,
Every
Box
for damage and connectors for security  not secured, or
?
6,000
and corrosion. Use corrosion preventive  corroded.
compounds (dielectric) on all electrical
contacts.
5
M
S
A
T
MI
Landing Legs
Check alignment of landing legs with a  Legs are not
Every
square. Legs must be parallel and parallel or square
?
6,000
square with trailer.
with trailer.
6
M
S
A
T
MI
Main Electrical
Check conditions of electrical harness
Harness is worn
Every
Harness and All
for wear, frayed insulation, corrosion,
through, corroded,
?
6,000
Electrical
and that connectors are secured. Use
or unsecured.
Connections
corrosion preventive compounds
Electrical
(dielectric) on all electrical contacts.
connections are
loose or corroded.