Operation Under Usual Conditions (Cont)
6
5
00602p
(6)
Turn main breaker (5) on breaker box (6) to ON position.
WARNING
Use extreme care when working around 120 VAC outlets.
Personnel may get electrocuted if 120 VAC outlet is
exposed to water. Failure to comply may result in injury
or death to personnel.
NOTE
Refer to circuit directory on rear module door for desired
breaker.
(7)
Turn desired breaker to ON position.
b. Stopping Hydraulic Generator.
CAUTION
All breakers must be turned off prior to turning main
breaker OFF. Failure to comply may result in damage to
equipment.
NOTE
Perform steps (1) through (4) to remove load from
hydraulic generator.
(1)
Turn all breakers to OFF position.
(2)
Turn main breaker (5) on breaker box (6) to OFF position.
(3)
Close rear compartment door (para 2-101).
(4)
Stow rear work platform (para 2-105).
|
||