TM 9-2320-279-10-3
Operation Under Usual Conditions (Cont)
3
4
tfft00296p
3
4
1
2
WARNING
Open and close all valves slowly during any procedure.
Sudden changes in pressure may cause equipment to
react faster than personnel can be alerted. Make sure
surrounding personnel are aware of changes being made
to settings on equipment. Failure to comply may result in
injury or death to personnel and damage to equipment.
NOTE
For operation of pump, most controls and procedures will
be the same whether pumping from tank, draft, or
hydrant.
Operator must make sure that:
(1)
ALL water discharge valve controls are in CLOSED position.
(2)
ALL water inlets are in CLOSED position.
(3)
ALL DRAINS are in CLOSED position.
(4)
ALL foam controls are in CLOSED/OFF position.
(5)
ALL inlet and outlet ports capped.
(6)
Make sure TANK FILL and RE-CIRCULATING LINE valve control (1)
is in CLOSED position. Indicator light (2) will come on.
(7)
Put PUMP COOLER switch (3) in OFF position. Check that Indicator
light (4) goes out.