Operation Under Usual Conditions (Cont)
2-110. WATER TANK FILL.
NOTE
The TFFT can be filled four different ways.
a. Main Inlet.
tfft00755ap
1
(1)
Make sure DRIVER MAIN INLET valve control (1) is closed.
tfft00754p
3
2
(2)
Remove cap (2) from driver main inlet (3).
WARNING
Do not use hard suction hose for step (3). Hard suction
hose will not hold pressure. Hose may fail and separate
causing injury to personnel and/or damage to equipment.
(3)
Connect 5 in. (13 cm) soft suction hose to driver main inlet (3) and
positive water source.
(4)
Open supply valve on positive water source.
|
||