Preventive Maintenance Checks and Services (PMCS) (Cont)
Table 2-9. Operator/Crew Preventive Maintenance Checks and Service (PMCS) (Cont)
NOTE: These checks are to be made in the order listed, within designated interval.
A-After Operation
D-During Operation
W-Weekly
M-Monthly
INTERVAL
ITEM TO BE INSPECTED PROCEDURE:
Item
Check for and have repaired, filled, or adjusted
NOT MISSION
No. A D W M
as needed.
CAPABLE IF:
6.
Generator Hydraulic Reservoir
a. Check hydraulic oil level. Fill as required. Refer
to Table 2-10 Lubricating Chart.
b. Check reservoir, hoses, and fittings for leaks.
Class III leaks are
evident.
tfft00111p
GENERATOR
HYDRAULIC
RESERVOIR
HYDRAULIC
SIGHT GLASS