Tweet |
Custom Search
|
|
|
||
TM 9-2320-279-10-3
Controls and Indicators (Cont)
7
tfft00943p
1
2
3
4
5
6
8
Hydraulic Generator FROG Display.
Key
CONTROL OR INDICATOR
FUNCTION
1
FREQUENCY LED Display
Displays generator output frequency in Hz.
Range: 0 to 99.9 Hz in one-tenth Hz increments.
2
AMPS LINE 1 and AMPS LINE 2 Displays amperage for each of two generator
LED Display
output lines. Range: 0 to 150 in one-Ampere
increments.
3
AC VOLTS LED Display
Displays generator output voltage. Range: 0 to
300 VAC in one-volt increments.
4
MODE Button
Allows user to switch sequentially through
STANDARD display mode, OPERATIONAL
HOURS display mode and ENGINE OIL
TEMPERATURE display mode.
5
OPERATIONAL HOURS Display Displays "HR" in the "FREQUENCY" LED
Mode
panel and total generator operating hours in the
"AMPS LINE 1" and "AMPS LINE 2" LED
panels. Range: 0 to 99999.9 hours in one-tenth
hour increments.
6
ENGINE OIL TEMPERATURE
Displays "OIL" in the "FREQUENCY" LED
Display Mode
panel and engine oil temperature in the "AMPS
LINE 1" LED panel. The "AMPS LINE 2" LED
panel displays "F." Range: 0 to 230F in
one-degree increments.
7
POWER ON Pilot Light
Illuminates when generator is engaged.
8
Fuses
Protect against circuit overload by interrupting
current flow if draw is above the circuit limit.
2-37
|
||