Tweet |
Custom Search
|
|
|
||
TM 9-2320-279-10-3
Controls and Indicators (Cont)
4
7
tfft00425p
5
6
1
2
3
Figure 2-50. Driver Side of Pump House.
Key
CONTROL OR INDICATOR
FUNCTION
1
NO. 1 DRIVER SIDE
Opens and closes discharge drain valve for
DISCHARGE Drain Valve
the No. 1 driver side discharge plumbing.
2
NO. 2 DRIVER SIDE
Opens and closes discharge drain valve for
DISCHARGE Drain Valve
the No. 2 driver side discharge plumbing.
3
DRIVERS PRE-CONNECT A
Opens and closes discharge drain valve for
Drain Valve
the drivers 1 in. pre-connect A discharge
plumbing.
4
NO. 1 Driver Side Discharge
Discharge connection for use with 2 in.
hose.
5
NO. 2 Driver Side 2 in.
Discharge connection for use with 2 in.
Discharge
hose.
6
120 VAC, 15 AMP, 60 Hz
Provides power for lights and other
Receptacle
accessories.
7
Driver Side Main Inlet
Used to fill water tank or to pump water
directly to water pump.
2-31
|
||