TM 10-6640-239-13
2-33
Table 2-12. Operator Preventive Maintenance Checks and Services (PMCS) - CONT
NOTE
If equipment must be kept in continuous operation, only do procedures that can be
performed without disturbing operation. Make the complete checks and services when
equipment can be shut down.
BE Before
AF After
MO - Monthly
DU- During
WE Weekly
Interval
Item No.
B
E
D
U
A
F
W
E
M
O
Item to Inspect
Procedures
Not Fully Mission
Capable If:
8
b. Inspect door microswitches.
Microswitches do not activate
properly when door is closed
and deactivate when door is
opened.
c. Inspect gasket.
Defective gasket.
d. Inspect motor for operation.
Motor does not operate.
e. Inspect filters.
Clogged, dirty, or defective
filter.
9
a. Inspect access doors for
defective or missing latches,
and hinges.
Door missing.
Main Power Panel
No. 1
b. Inspect circuit breakers for
damage.
Circuit breakers loose or
damaged.
10
a. Inspect access doors.
Door missing.
Power Panel
No. 2
b. Inspect circuit breakers for
damage.
Circuit breakers loose or
damaged.
11
Emergency
Lights
Inspect for illumination.
Lights do not illuminate.
12
a. Inspect mounting bolts.
Loose or missing mounting
bolts.
b. Inspect crankcase oil level.
Low oil level.
c. Inspect intake filter.
Clogged or dirty filter.
d. Check for rattles, knocks,
squeaks, or hums that may
indicate trouble in air
compressor or motor.
Vibration or unusual noise
occurs.
Air Compressor
e. Inspect motor for indication
of overheating and smoke.
Motor overheats or emits smoke.
13
Ladder
Inspect for presence.
Ladder missing.
14
Air Tank and
System Piping
a. Inspect mounting bolts.
Loose or missing mounting
bolts.
|
|