TM 10-6640-239-13
2-32
Table 2-12. Operator Preventive Maintenance Checks and Services (PMCS) CONT
NOTE
If equipment must be kept in continuous operation, only do procedures that can be
performed without disturbing operation. Make the complete checks and services when
equipment can be shut down.
BE Before
AF After
MO - Monthly
DU- During
WE Weekly
Interval
Item No.
B
E
D
U
A
F
W
E
M
O
Item to Inspect
Procedures
Not Fully Mission
Capable If:
4
a. Inspect for damage.
Panel damaged or missing hinge.
b. Inspect power cable
connector.
Defective connector. Loose,
missing or damaged pins.
Power Panel
c. Inspect ground cable for
proper connection to ground
lug and grounding rod.
Grounding connections are
damaged. Safety clip missing.
5
Power Cables
Inspect cable for damage.
Cable connector or cable has
cuts and deep abrasions.
6
Environmental
Control Units
(ECUs)
Inspect bellows.
Bellows damaged.
Mounts loose or missing.
ECUs do not operate.
Retaining cable damaged or
missing.
7
a. Inspect access door.
Latches, keepers, seals, ball
studs, or hinges damaged or
missing.
b. Inspect door microswitches.
Microswitches do not activate
properly when door is closed
and deactivate when door is
opened.
c. Inspect gasket.
Defective gasket.
d. Inspect motor operation.
Motor does not operate.
Purge Exhaust
Doors
e. Inspect filters.
Clogged, dirty, or defective
filter.
8
Purge Intake
Doors
a. Inspect access doors.
Latches, keepers, seals, ball
studs, or hinges damaged or
missing.
|
|