4-45. KINEMATIC VISCOSITY BATH.
This task consists of:
a.
Remove
b.
Install
INITIAL SET-UP
Tools Required
General Mechanics Tool Kit, (Appendix B, Section III, Item 1)
General Safety Instructions
WARNING
ELECTRICAL SHOCK
Before performing any maintenance actions on electrical equipment, ensure all
electrical power has been turned off. Failure to comply with this warning may
result in serious injury or death.
REMOVE
Remove Kinematic Viscosity Baths. See Figure 4-41.
a.
Unplug controller (1) for viscosity bath (2) from wall receptacle.
b.
Disconnect strap (3) and remove top bracket (4) from viscosity bath (2).
c.
Lift controller (1) from viscosity bath (2).
d.
Loosen four captive wing bolts (5) and remove two hold down brackets (6).
e.
Remove viscosity bath (2).
INSTALL
Install Kinematic Viscosity Baths. See Figure 4-41.
a.
Install viscosity bath (2) in place on foundation.
b.
Install two hold down brackets (6) and secure with four captive wing bolts (5).
c.
Lower controller (1) into viscosity bath (2).
d.
Place top bracket (4) with strap (3) in position on viscosity bath (2) and secure strap.
e.
Plug controller (1) for viscosity bath (2) into wall receptacle.
f.
Verify viscosity bath operation.
NOTE
For component removal refer to commercial manual.
|
|