TM 10-6640-215-13
2-2. OPERATOR CONTROLS AND INDICATORS - continued .
Table 2-10. Gum Bath System Controls and Indicators
Control or Indicator
Function
Pyrometer
Indicating and controlling device for gum bath preset
temperatures.
Air Flow Indicator
Provides indication of air flow to gum bath. Calibrated in
pounds and ounces, corresponding to flow of air in liters per
second.
Air Flow Regulator
Regulates air to gum bath. The rate of flow required is 1
liter per second ( 15 %).
Temperature Control (Steam)
Control temperature of the high pressure boiler steam output
up to 5500F (228°C).
AUX Switch
Turns the high pressure boiler heater circuit ON or OFF.
INT Switch
Turns the internal heaters of the gum bath ON or OFF.
GUM BATH Hood Light Switch
Controls hood light operation.
Fume Hood Light Switch
Controls hood light operation.
Fume Hood and Gum Bath Hood
Controls exhaust fans operation.
Exhaust Fan Switches and Indicator Lights
Indicator lights are on to indicate exhaust fan operation.
Boiler ON/OFF Switch
Controls operation of low pressure boiler.
Low Pressure Boiler Automatic
Maintains low pressure boiler water level.
Water Feeder System
Operating Control
Maintains low pressure boiler steam output to gum bath.
HI Limit Control and Pressure
Protects boiler from damage if boiler pressure if too high.
Relief Valve
Boiler Sightglass
Indicates water level in low pressure boiler.