TM 10-6640-215-13
1-11. LOCATION AND DESCRIPTION OF MAJOR COMPONENTS - continued.
Overpack Boxes: Eight overpack boxes provide storage for supplies and equipment
shipped with the Petroleum Laboratory.
Vacuum Pump: The vacuum pump is a 2-stage rotary pump which provides vacuum to
the laboratory vacuum system.
1-12. EQUIPMENT DATA.
Exterior Dimensions
Length ....................................................................................................................................... 35.42 ft (10.80 m)
Width ............................................................................................................................................. 8.00 ft (2.44 m)
Height .......................................................................................................................................... 11.71 ft (3.57 m)
Interior Dimensions
Length (Laboratory Compartment) ............................................................................................... 27.29 ft (8.32 m)
Length (Mechanical Room) ............................................................................................................ 7.75 ft (2.36 m)
Width (Both) ............................................................................................................................... 7.50 ft (2.29 m)
Height (Laboratory Compartment).................................................................................................. 7.55 ft (2.30 m)
Height (Mechanical Room.............................................................................................................. 6.64 ft (2.03 m)
Total Interior Cubage (Laboratory Compartment) ......................................................................1545.30 ft3 (43.77 m3)
Total Interior Cubage (Mechanical Room) ...................................................................................385.95 ft3 (10.93 m3)
Power Requirements ........................................................................................................ 208V, 60Hz, 3-phase, 5-wire
Electrical Connections
Power .................................................................................... One 208V, 60Hz, 3-phase, 5-wire power input cable
Ground ..................................................................................................................Ground lug to ground rod cable
Environmental Control (Heating and Cooling)
Model................................................................................................ Four Model F18T-2S Vertical Compact Units
Rating ..............................................................................................................................(Cooling) 18,000 BTU/Hr
(Heating) ........................................................................................................................................12,000 BTU/Hr
Power ..............................................................................................................................208V, 3-phase, 50/60 Hz
Control.................................................................................................................................................... Individual
Air System
Air Compressor ................................................................. .Model LE6 A, with 208V, 60Hz, 3-phase, 3-hp motor
Air Tank Capacity ............................................................................................................... 30 gallon (113.55 1)
Vacuum Pump ........................................................................................................................................Model 1405B
Free Air Capacity ..................................................................................................................... 58 liters per minute
Motor ....................................................................................................................................... 1/2-hp, 115V, 60Hz
1-20
|
|