TM 10-6640-215-13
4-45. REMOVE/INSTALL KINEMATIC VISCOSITY BATHS.
This task covers:
a. Removal
b. Installation
INITIAL SETUP:
Tools Required
General Mechanics Tool Kit, (Appendix B, Section III, Item 2)
Materials/Parts Required
Lockwashers, (Appendix F)
General Safety Instructions
WARNING
ELECTRICAL SHIOCK
Before performing any maintenance actions on electrical equipment, ensure all electrical power
has been turned off Death or serious injury may occur from failure to do this.
REMOVAL
Remove Kinematic Viscosity Baths. See figure 4-45.
a.
Unplug controller for viscosity bath from wall receptacle and unplug bath from controller.
b.
Disconnect strap which secures the top bracket over viscosity bath. Remove bracket.
c.
Loosen four captive wing bolts and remove hold down brackets.
d.
Remove viscosity bath.
e.
Remove controller for viscosity bath by removing the two nuts, lockwashers, and flat washers from the retaining
bracket.
INSTALLATION
Install Kinematic Viscosity Baths. See figure 4-45.
a.
Install controller for viscosity bath by installing retaining bracket. Secure with two flat washers, lockwashers, and
nuts.
b.
Place viscosity bath in position on foundation.
4-122
|
|