Custom Search
 
  
 


TM 10-6640-215-13 1-11.  LOCATION AND DESCRIPTION OF MAJOR COMPONENTS - continued. Rear Door: Primarily used to load and unload overpack boxes.  Provides a secondary entrance/exit for the laboratory.  Provided with an internal door lock release mechanism to facilitate emergency exit. b. Front and Roadside Exterior. POWER INPUT Panel Door: Hinged, double latched access door to electrical and telephone connection points.   An alarm buzzer which indicates a purge door closed during a purge cycle is also located behind this door. Roadside Storage Box: Provides storage area for main power input cable, ground rod, ground rod driver/puller, hose adapter, coupler and fire hose.  It is equipped with fork truck lift slots and retaining pins for installation/removal. Fume Hood and Gum Bath Vent Door: Hinged, double latched access door for fume hood and gum bath vent.   Must be open when operating exhaust blowers. Utilities Box Door- Hinged, double latched access door to water connections for hoses to fill, supply or drain the water system. PURGE INTAKE Door: Hinged, double latched access door for purge intake damper. Must be open during purge cycle to allow environmental control unit to ventilate the laboratory. PURGE EXHAUST Door: Hinged, double latched access door for purge exhaust damper. Must be open during purge cycle to allow air to be exhausted from the laboratory. Trailer Accessories Storage Door: Provides access to storage area for van accessories; i.e., roadside reflectors, wheel chocks, various tools, wiping rags, etc. Environmental Control Units: Provide heating and cooling of the laboratory.  The four units are identical but each has its own individual controls. c. Interior. Jet Fuel Thermal Oxidation Tester: This tester is a closed loop fuel system with pump circulation and nitrogen pressurization.  It is used in performing ASTM test D-3241. Oxidation Stability Bath: Used with Oxidation stability of Gasoline Bomb to perform ASTM tests D-525 and D- 873. Pressure Recording Gage: Provides a means to measure and record pressure changes in a system.  Changes are plotted against time.  It is used in conjunction with the Oxidation Stability Bath. Reid Vapor Pressure Bath: Used with Reid Vapor Pressure Bombs to perform ASTM tests D-323 and D-1267. Manometer: A dual-scale (psi and Hg) indicator which provides a means of accurately testing RVP gages before and after use. 1-12


 


Privacy Statement - Copyright Information. - Contact Us

Integrated Publishing, Inc. - A (SDVOSB) Service Disabled Veteran Owned Small Business