TM 10-6640-215-13
4-39. REMOVE/INSTALL COMPONENTS OF WATER SYSTEM.
This task covers:
a. Removal
c. Test
b. Installation
INITIAL SET-UP:
Tools Required
General Mechanics Tool Kit, (Appendix B, Section III, Item 2)
General Safety Instructions
WARNING
ELECTRICAL SHOCK
Before performing any maintenance actions on electrical equipment, ensure
all electrical power has been turned off. Death or serious injury may occur
from failure to do this.
REMOVAL
1.
Remove Water Filter. See figure 4-29.
NOTE
Filter element replacement requires only that the bowl be unscrewed from filter cover.
a.
Set switch on pump controller to OFF.
b.
Open circuit breaker A15CB8 on Power Panel No. 2.
c.
Close isolation valves on each side of filter.
d.
Remove water filter element retaining bolt.
e.
Remove bowl and remove filter element.
2.
Remove Water Pressure Switch. See figure 4-30.
a.
Remove switch cover, tag leads for reconnection and disconnect switch leads.
b.
Remove lock nut from conduit and remove conduit.
c.
Turn water piping union and unscrew defective pressure switch from piping.
d.
Remove water pressure switch.
4-93
|
|