TM 10-6640-215-13
4-34. REPAIR PURGE EXHAUST DOOR, CURBSIDE.
This task covers:
a. Removal
b. Installation
INITIAL SET-UP:
Tools Required
General Mechanics Tool Kit, (Appendix B, Section III, Item 2)
Drill and Bits, (Appendix B, Section II, Item 1)
Drill Set, (Appendix B, Section III, Item 1)
Hand Blind Riveter, (Appendix B, Section III, Item 3)
Materials/Parts Required
Gasket, (Appendix F)
Adhesive MM-A-1617, Type II, (Appendix E, Section II, Item 3)
Rivets, (Appendix F)
NOTE
Procedures for performing this task are identical to those outlined in paragraph 4-29. Refer to that
paragraph and Figure 4-18.
4-35. REMOVE/INSTALL CURBSIDE EXHAUST DAMPER MOTOR.
This task covers:
a.
Removal
b. Installation
INITIAL SET-UP:
Tools Required:
General Mechanics Tool Kit, (Appendix B, Section III, Item 2)
General Safety Instructions:
WARNING
ELECTRICAL SHOCK
Before performing any maintenance actions on electrical equipment, ensure all
electrical power has been turned off. Death or serious injury may occur from failure to
do this.
REMOVAL
Remove Curbside Exhaust Damper Motor. See figure 4-22.
a.
Inside the laboratory, remove eight screws and flat washers and remove screen from exhaust housing.
b.
Remove two screws and cover from 2" x 4" junction box located adjacent to exhaust housing. Tag for
reconnection and disconnect motor leads. Attach line to leads to facilitate installation.
4-78
|
|