TM 10-6640-215-13
Table 4-1. Unit Preventive Maintenance Checks and Services
Item
Interval
Item To Be
Procedure
Not Fully Mission
No.
Checked Or
Capable
Serviced
10
Quarterly
Water System
NOTE
Refer to TM 10-4320-321-13&P
for further PMCS
instructions.
a. Check water pump for damage.
Check
mounting
hardware
and
electrical connections.
Pump does not operate
properly. Mounting hard-
ware is loose or missing.
missing.
b. Check water tank for leaks.
Water tank leaks. Mount-
Check
mounting
hardware
and
electrical connections
ing hardware is loose or
c. Check surge tank for leaks.
Tank or fittings leak.
Check mounting hardware.
Mounting hardware is loose
or missing.
d. Check water pressure switch
Switch or gage does not op-
and gage for proper operation.
erate properly. Mounting
Check
mounting
hardware
and
electrical connections
hardware loose or missing.
.
Water tank leaks. Mount-
e. Check water chiller for leaks.
ing hardware is loose or
Check mounting hardware.
missing.
NOTE
Refer to TM 10-4130-240-
13&P for further PMCS
instructions.
f. Check water chiller for proper
Water chiller does not oper-
operation. Check mounting hard-
ate properly. Mounting
ware and electrical connection.
hardware loose or missing.
g. Check water heater for leaks.
Water heater leaks. Mount-
Check
mounting
hardware
and
electrical connections.
ing hardware is loose or
missing.
h. Check electric still for proper
Electric still does not oper-
operation. Check mounting hard-
ate properly. Mounting
ware and electrical connection.
hardware is loose or mis-
sing.
i. Check drain tank for leaks.
Tank, tubing, piping, or fit-
Check
mounting
hardware
and
electrical connections.
tings leak. Mounting hard-
4-8
|
|