TM 10-6640-215-13 3-5. REMOVE/INSTALL PURGE INTAKE DOOR  FILTERS-continued.. b. Replace purge door .circle and fasten in place with four screws and lockwashers. 3-6. REMOVE INSTALL PRESSURE RECORDING GAGE. This task consists of: a. Removal b. Installation INITIAL SET-UP: Tools Required General Mechanics Tool Kit, (Appendix B, Section III, Item 2) Equipment Conditions All inputs to pressure gage disconnected. REMOVAL Remove Pressure Recording Gage.  See figure 3-3. a. Remove  three  hex-head  mounting  bolts  and  carefully  remove  pressure  recording  gage  from  wall mounts. b. Refer   to   T.M      10-6685-365-13&P   for   adjustment   or   repair   procedures   required   for   the   pressure recording gage. INSTALLATION Install Pressure Recording Gage. a. Align pressure recording gage with wall mounts. b. Fasten pressure recording gage to wall mounts with three hex-head bolts. 3-20


 