TM
10-4930-251-12&P
General Safety Instructions
WARNING
Do not smoke or have open flame within
50 feet of dispensing
unit.
Dry cleaning solvent is potentially
dangerous to personnel and property.
NOTE
Discard all mandatory replacernent
parts.
NOTE
In the folloving,
mainteriance procedures two cables installed are depicted.
You need only concern yourself with
single cable installation.
That cable is installed in No. 1(inboard) position.
a. Control
Box Assembly Levers Maintenance.
1
Removal.
(a)
Loosen nuts (1) to disconnect cables (2) frorn the adjusting bolt (3). See Figure
4-14.
(b)
Remove the nuts (1) and withdraw
cables (2) through bushing (4).
(c)
Remove screw (5) and lock washers (6) to remove lever assembly (7) from
Control
Box Assembly.
2
2
4
3
No. 1
Position
No. 2
Position
5
7
Figure 4-14
Control
Box Assembly
Control
Levers
4-19
|
|
|
|