Custom Search
 
  
 


TM 9-2330-380-14&P
Table 4-2. Unit Troubleshooting (cont'd)
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
Step 2. Check if door is hard to lock.
If door is hard to lock, add shim stock as required under handle door lock and/or slide bolt
assemblyguides.
If door is not hard to lock, proceed to step 3.
Step 3. Check for good weather tight seal when door is in closed and locked position.
Add shim stock as required under slide bolt assemblies.
Replace defective lock assembly (para. 4-68).
24. DOOR HINGES DO NOT OPERATE PROPERLY
Step 1. Check for rust on hinge pin.
Remove rust and lubricate.
Step 2. Check for cracked or broken hinge.
Replace defective hinge (para. 4-65).
25. RFI SHIELDING DOES NOT PROVIDE GOOD CONDUCTIVITY (XM1063 ONLY)
Check for dust, grime and dirt on RFI seals and contact areas.
Seals and contact areas must be kept clean at all times to provide good conductivity.



 


Privacy Statement - Copyright Information. - Contact Us

Integrated Publishing, Inc. - A (SDVOSB) Service Disabled Veteran Owned Small Business