Custom Search
 
  
 


TM 9-2330-380-14&P
4-46. Brake Air Chamber (cont'd)
WARNING
Dry cleaning solvent (P-D-680) is toxic and flammable. Avoid prolonged breathing of vapors.Avoid
skin contact. Use only in a well-ventilated area. Keep away from open flame. Flash point of solvent
is 138o F (50o C).
2. Remove grease and oil with dry cleaning solvent (item 3, Appendix E) using a soft cloth (item 14,
e. Inspection
1. Inspect for loose, missing or damaged parts.
2. Inspect air chamber for cracks, dents, holes and warps.
3. Inspect for rust, corrosion and marred paint. Clean, treat, prime and paint as required.
4. Replace defective parts.
f. Installation
WARNING
If installing a new brake air chamber, make sure it is caged prior to installation. Failure to do so
could result in serious injury to personnel or damage to equipment.
NOTE
Apply teflon tape (item 12, Appendix E) to threads of air line connections before installation.
1. Position air chamber (10) and secure with two nuts (8) and washers (9).
2. Position yoke pin (7) and secure with cotter pin (6).
4-76



 


Privacy Statement - Copyright Information. - Contact Us

Integrated Publishing, Inc. - A (SDVOSB) Service Disabled Veteran Owned Small Business