Tweet |
Custom Search
|
|
|
||
TM 9-2330-380-14&P
4-29. Intervehicular Cable Receptacle, 12-Volt (cont'd)
b. Cleaning
WARNING
Cleaning compound is toxic and flammable. Avoid prolonged breathing of vapors. Avoid skin
contact. Use only in a well-ventilated area. Keep away from open flame. Flash point of compound
is 120o F (49o C).
Clean all parts with cleaning compound (item 19, Appendix E)
and clean rags (item 14, Appendix E).
c. Inspection
1. Inspect for cracks, breaks or other damage.
2. Replace defective parts.
d. Installation
1. Insert each wire into its proper position at rear of
receptacle and secure with screws (5) (refer to wiring
diagrams, pages 4-58, 4-59, 4-65, or 4-66).
2. Position receptacle (4) and secure with two screws (1),
washers (2) and nuts (3).
3. Make certain power source is disconnected and make a
continuity check of all circuits throughout semitrailer, using a
Follow-on maintenance: None
4-43
|
||