0047 00
 
 
TRUNNION BUSHING MAINTENANCE 
1 
2 
3 
7 
6 
4 
5 
Figure 1. Trunnion Bushing 
INSTALLATION 
1.	 	 Position new trunnion bushing (6) on tube (7) and equalizing beam (4). 
2.	 	Install trunnion cap (3) with four screws (5), and new flange nuts (2). Torque flange nuts to 
600 Ib-ft (814 Nm) lubricated. 
3.	 	 Remove floor jack from under trunnion bracket (1). 
FOLLOW-ON TASKS 
 Install wheels (WP 0016 00-3). 
END OF WORK PACKAGE 