Tweet |
Custom Search
|
|
|
||
TM 9-2330-330-14&P
FUEL LEVEL SENSOR AND SENSOR TUBE MAINTENANCE--Continued
0121 00
INSTALLATION
1.
Install new gasket (15), sensor tube (13), sensor (5), and five screws (14).
2.
Install plate (11), coupling halves (10), two new lockwashers (9), and bolts (8) to support
bracket (12).
3.
Install conduit (7) and conduit nut (6) to sensor (5).
4.
Connect six sensor wires (4) and one ground wire (3) to sensor (5).
5.
Close cover (2) and tighten three screws (1).
FOLLOW-ON TASKS
1.
Reconnect negative battery terminal (WP 0007 00).
2.
Disconnect semitrailer grounding cables (WP 0007 00).
END OF TASK
0121 00-3/4 blank
|
||