INSPECTION
Inspect wiring harness for cracked or missing insulation, frayed or exposed wires, and loose or damaged
connectors. If any of these conditions exist, repair per WP 0065 00.
INSTALLATION
1.
Install side marker light harness wires (9 and 12) through conduit (8) to junction box (11) from
curbside marker light box (4).
2.
Install new connectors (6) on all wires (5) per WP 0065 00.
3.
Connect wire (12) to terminal strip (13) in junction box (11).
4.
Connect wire (9) to grounding strip (10) in junction box (11).
5.
Connect two wires (5) and connectors (6) to marker light leads (7) in curbside box (4).
6.
Install marker light cover (3), new gasket (2), and four screws (1) to curbside marker light box (4).
FOLLOW-ON TASKS
1.
Disconnect semitrailer grounding cables (WP 0007 00).
2.
Reconnect negative battery terminal (WP 0007 00).
END OF TASK