TM 9-2330-330-14&P
FUEL-DISPENSING NOZZLE AND PUMP STRAINER MAINTENANCE
0041 00
AND MANUAL PUMP PRIMING--Continued
SERVICE
NOTE
Screen in nozzle coupling must be cleaned periodically and
whenever flow through nozzle is restricted.
1.
Remove clip ring (4) and screen (3) from inside of nozzle coupling (2).
WARNING
Solvents can burn easily, can give off harmful vapors, and are
harmful to skin and clothing. To avoid injury or death, keep away
from open fire and use in a well-ventilated area. If solvent gets on
skin or clothing, wash immediately with soap and water.
2.
Clean screen (3) with cleaning compound and rag. Use compressed air to dry screen and remove
any excess material.
3.
Install screen (3) and clip ring (4) in nozzle coupling (2).
0041 00-2



 